2000 Counts Hand - Held Digital Multimeter With AC/DC Current , Capacitance And Resistance Tester
English User Manual:https://drive.google.com/open?id=1oeQG3TCPgh1g2I_suK1k1lgjkjvbbaQw
Features of Handheld Digital Multimeter
- Fuse FF 250mA/250V F 10A/500V
- Battery saving energy function
- Measuring AC and DC voltage
- Measuring resistance
- Audible continuity testing
- Measuring capacitance
- Transistor measuring
- Testing diode
Specifications | Range | Accuracy |
DC Voltage | 200mV/2V/20V/200V | ±(0.5%+1) |
1000V | ±(0.8%+2) |
AC Voltage | 200mV | ±(1.2%+3) |
2V/20V/200V | ±(0.8%+3) |
750V | ±(1.2%+5) |
DC Current | 2mA/20mA | ±(0.8%+1) |
200mA | ±(1.5%+1) |
10A | ±(2.0%+5) |
AC Current | 2mA/20mA | ±(1.0%+3) |
200mA | ±(1.8%+3) |
10A | ±(3.0%+7) |
Resistance | 200Ω | ±(0.8%+3) |
2kΩ/20kΩ/200kΩ/2MΩ | ±(0.8%+1) |
20MΩ | ±(1.0%+1) |
200MΩ | ±(5.0%+10) |
Capacitance | 20nF/200nF/2µF/20µF | ±(4.0%+3) |
200µF | ±(5.0%+10) |
Features |
Display | 2000 counts |
Data Hold | √ |
Auto Power Off | √ |
Diode Test | √ |
Transistor Test | √ |
Continuity | √ |
General |
Power Supply | 1*9V6F22 battery |
Net weight | Approx.339g (battery is not included) |
Gross weight | 542g |
Size | 193mm*93mm*50mm |
Safety Rating | EN61010-1, EN61010-2-033, EN61326, CAT. Ⅲ 1000V |
Descriptions of Handheld Digital Multimeter
This digital multimeter has been designed according to the International Electro Safety Standard IEC – 61010 concerning safety requirements for electronic measuring instruments and hand-held digital multimeters. This meter can measure AC&DC voltage, AC&DC current, resistance, capacitance.
- Measurement type IV (CAT. IV), to use the entrance from repair port to power meter and the primary over-current protection deviceMeasurement type III (CAT. III) is the measurement made within the building equipment.
- Usage: For example, wiring of switchboard and circuit protector within fixed equipment includes cable, bus bar, junction box, switch, socket output end, equipment for industrial purposes and other equipment (such as permanently connected to fixed motor of fixed equipment) for measurement.
- Measurement type II (CAT. II) is the measurement made on the circuit which is connected directly to low voltage equipment.
- Note: For example, measuring household equipment, portable instruments and similar devices.
- Measurement type I (CAT. I) is the measurement made on the circuit which is not directly connected with bus bar.
- Note: For example, the measurement which is not made on the circuit not derived from bus bar and special (internal) protection bus circuit. (For the latter, the instant overload varies, so the instant overload resistance of equipment must be clearly marked.)